| B-601H-R - Rate-of-Rise Heat Detector |
 |
 |
Detects abnormally high rates of rise of temperature |
 |
 |
Heat detectors offer an acceptable, but less sensitive alternative to smoke detectors if environmental conditions rule out their use |
 |
 |
For general use and particular where the ambient temperature may be low |
 |
 |
EN 54 approved by LPCB |
 |
 |
Low operational voltage: 10.5v to 33v |
|
 |
 |
|
 |
 |
 |
| B-601H-R - Rate-of-Rise Heat Detector |
 |
 |
Detects abnormally high rates of rise of temperature |
 |
 |
Heat detectors offer an acceptable, but less sensitive alternative to smoke detectors if environmental conditions rule out their use |
 |
 |
For general use and particular where the ambient temperature may be low |
 |
 |
EN 54 approved by LPCB |
 |
 |
Low operational voltage: 10.5v to 33v |
|
 |
 |
|
 |
 |
 |
| B-601P - Optical Smoke Detector |
 |
 |
Suitable for general applications and areas |
 |
 |
Capable of detecting the visible smoke produced by materials which smoulder or burn slowly, i.e. soft furnishings, plastic foam etc., or smoke produced by overheated but unburnt PVC |
 |
 |
Asymmetrical sampling chamber and signal processing techniques stop unwanted alarms caused by very small insects |
 |
 |
EN 54 approved by LPCB |
 |
 |
Low operational voltage: 10.5v to 33v |
 |
 |
Designed for rapid installation |
 |
 |
Wiring polarity independent |
 |
 |
Ordering no. 76B-601P |
|
 |
 |
|
 |
 |
 |
| H900/R24/R24S - Horn, Red, 24V |
 |
 |
Operating voltage: 19 / 32 Vdc |
 |
 |
Strobe current draw (mean value): 90 mA |
 |
 |
Sound output height / low volume: 87± 3dB / 100±3dB @ 3m |
 |
 |
Candela: 60 cd |
 |
 |
Dimensions: (wxhxd): 126x132x53 mm |
 |
 |
Protection class: IP31 |
 |
 |
Operating temperature: 5 / 40 °c |
|
 |
 |
|
 |
 |
 |
| HS900/ R24/ R24S - Horn/Strobe, Red, 24V, Not Synchronized |
 |
 |
Synchronized version : HS900/R24 |
 |
 |
Not synchronized version : HS900/R24 |
 |
 |
Operating voltage: 19 / 32 Vdc |
 |
 |
Strobe current draw (mean value): 90 mA |
 |
 |
Sound output height / low volume: 87± 3dB / 100±3dB @ 3m |
 |
 |
Candela: 60 cd |
 |
 |
Dimensions: (wxhxd): 126x132x53 mm |
 |
 |
Protection class: IP31 |
 |
 |
Operating temperature: 5 / 40 °c |
|
 |
 |
|
 |
 |
 |
| J400-BRG - Fire Panel Serial Interface |
 |
 |
Enables PC communication with J400 series fire control panels via RS485 bus |
 |
 |
Receives data from zones and peripherals and transmits commands to the system |
|
 |
 |
|
 |
 |
 |
| J400EXP8 - 8 Zones Expander Module for J424 Panels |
 |
 |
8 balanced, by passable fire zones |
|
 |
 |
|
 |
 |
 |
| J400EXT - Extinguisher Module with Microprocessor Control |
 |
 |
Output for electro-valves controlled by logic (AND / OR) between the status of the control panel zones |
 |
 |
Programmable extinguishment delay |
 |
 |
Output signals: extinguishment delay, extinguishment and released devices |
 |
 |
Fault signalling on input lines |
 |
 |
Bypass of extinguishment devices in the event of false alarm |
 |
 |
Inputs for selecting manual or automatic mode, extinguishment inhibit and power supply supervision |
 |
 |
Ordering no.76B-J400-EXT |
|
 |
 |
|
 |
 |
 |
| J400-LCD - Display Module |
 |
 |
Back lit LCD display module, lines with 16 characters per line |
 |
 |
Main text regarding the system’s status and it is equipped with 6 scroll keys |
 |
 |
Ordering no.76B-J400-LCD |
|
 |
 |
|
 |
 |
 |
| J400-REP - Repeater Panel |
 |
 |
4 wire connection to the panel (power supply included) |
 |
 |
The repeater panel may be installed up to 1.000 m from the control panel |
 |
 |
Displays all audible and visual signalling |
 |
 |
Control panel management |
|
 |
 |
|
 |
 |
 |
| J408-2 / J408-4 / J408-8 - 2 / 4 / 8 Zone Conventional Fire Control Panel |
 |
 |
8 controlled, balanced, bypassable input zones (J408-2 has 2 zones, J408-4 has 4 zones) |
 |
 |
Conforms with EN54 |
 |
 |
Up to 21 devices can be connected to each zone: conventional fire detectors, alarm buttons, gas det |
 |
 |
Gas zone compatible with 4-20 mA gas detectors |
 |
 |
One alarm-repeat output (open collector) for each input zone |
 |
 |
Silenceable fault warning output for the activation of signalling and auxiliary devices |
 |
 |
Dry contact alarm-relay for the activation of auxiliary devices |
 |
 |
Alarm verification time |
 |
 |
Programmable from PC or keypad |
 |
 |
Ordering no. 76BJ408-2/4/8 |
|
 |
bentel fire product catalogue |
 |
|
 |
 |
 |
| J424-8 - BENTEL |
 |
 |
8 controlled, balanced, bypassable input zones expandable to 24 by means of two 8 zone expander |
 |
 |
Conforms with EN54 |
 |
 |
Up to 21 devices can be connected to each zone: conventional fire detectors, alarm buttons, gas det |
 |
 |
Gas zone compatible with 4-20 mA gas detectors |
 |
 |
One alarm-repeat output (open collector) for each input zone |
|
 |
bentel conventional fire product catalogue |
 |
|
 |
 |
 |
| MCP900RCS - Conventional, Restorable Call Point with Alarm LED |
 |
 |
Stylish easy-to-install manual call point |
 |
 |
Ideal for internal environments that require manual activation and inhibition of fire alarms and fire exting |
 |
 |
Also suitable for door escalator control |
 |
 |
The manual call point can be activated by pushing the centre |
 |
 |
Reset by means of special key |
 |
 |
Ordering no.76B-MCP900RCS |
|
 |
 |
|